Diabetes care · Diabetologia · 2025
Summary: video visits “superior” on blood sugar. The paper’s own range: chance could easily explain it.
How often chance alone would produce this gap if video made no real difference
The paper says
In a diabetes trial, a blood test of average blood sugar fell 4.13 points with video visits and 2.12 with in-person visits. The summary calls video “superior”. The table’s p, below 0.001, says chance alone would produce a 2.01-point gap under 1 time in 1,000.
Its own data show
The table also gives the range of gaps its data fit: 5.32 points more fall with video to 1.29 more with in-person visits, including zero, a tie. From that range, chance alone would produce this gap about 1 time in 4 (p = 0.23). Each group’s own margin of error gives a wider range still.
A p-value is how often chance alone would produce a gap this big if video made no real difference; the usual bar is under 1 in 20 (0.05). A range like this that includes zero always means p above 0.05. The summary’s other claims, that video patients were more satisfied yet had worse quality of life, have the same mismatch.